Offering you a complete choice of products which include gemtech series 3000 digital pressure gauge range 0 to 2.000 kpa - siliguri darjeeling, gemtech series 3000 digital pressure gauge range 0 to 0.500 kpa in siliguri,darjeeling west bengal, gemtech series 3000 digital pressure gauge- range 0 to 3.000 kpa - west bengal, gemtech series 3000 digital pressure gauge- range 0 to 5.000 kpa in sree kaliyamvelli devi temple, gemtech series 3000 digital pressure gauge- range 0 to 3.000 kpa in delhi haryana faridabad and gemtech series 3000 digital pressure gauge- range 0 to 1.000 kpa llrm medical college,meerut.
₹ 18,500 /Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 2.000 KPA - Siliguri Darjeeling |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Warranty | 1 Year |
Product Weight | 250 g |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 2.000 KPA - Siliguri Darjeeling.Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.500 KPA in Siliguri,Darjeeling West Bengal |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.500 KPA in Siliguri,Darjeeling West Bengal |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Net Weight | 250 g |
Automation Grade | Automatic |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.500 KPA in Siliguri,Darjeeling West Bengal
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 VDC |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Mounting | Bottom |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 3.000 KPA - West Bengal |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Brands | GEMTECH |
Product Weight | 250 g |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 3.000 KPA - West BengalThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Bottom |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 5.000 KPA in Sree Kaliyamvelli Devi Temple |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Automation Grade | Automatic |
Product Weight | 250 g |
Brands | GEMTECH |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 5.000 KPA in Sree Kaliyamvelli Devi Temple Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 Vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 3.000 KPA in Delhi Haryana Faridabad |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Automation Grade | Automatic |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Product Weight | 250 g |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 3.000 KPA | Delhi Haryana Faridabad Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 Vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 1.000 KPA LLRM Medical College,Meerut |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Product Weight | 250 g |
Brands | GEMTECH |
Frequency Range | GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 1.000 KPA LLRM Medical College,Meerut |
Automation Grade | Automatic |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge- Range 0 to 1.000 KPA LLRM Medical College,MeerutThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | GEMTECH Series 3000 Digital Pressure Gauge Range 0.750 KPA in Ramesh Nagar New Delhi |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0.750 KPA in Ramesh Nagar New Delhi |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Net Weight | 250 g |
Frequency Range | GEMTECH Series 3000 Digital Pressure Gauge Range 0.750 KPA in Ramesh Nagar New Delhi |
Automation Grade | Automatic |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0.750 KPA in Ramesh Nagar New DelhiThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 VDC |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.250 KPA from Gumla |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Frequency Range | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.250 KPA from Gumla |
Weight | 250 g |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Brands | GEMTECH |
Automation Grade | Automatic |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.250 KPA from GumlaThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Analog |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Stainless Steel |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 10.00 KPA in Chainpur block Gumla |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Product Weight | 250 g |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Brands | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 10.00 KPA in Chainpur block Gumla |
Frequency Range | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 10.00 KPA in Chainpur block Gumla |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 10.00 KPA in Chainpur block GumlaThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 VDC |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.125 KPA in Chainpur block Gumla |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Brands | GEMTECH |
Automation Grade | Automatic |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Weight | 250 g |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.125 KPA in Chainpur block GumlaThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18,500 /Piece Get Latest Price
Power Source | 24 VDC |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.060 KPA Rajahmundry |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Product Weight | 250 g |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Automation Grade | Automatic |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 0.060 KPA RajahmundryThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
DP Sharma (Proprietor)
D.P.Engineers
X/852, Chand Mohalla, Street No.11, Gandhi Nagar
New Delhi - 110031, Delhi, India